Technical Specifications
Technical Details
Genset Specifications | |
Genset Model | GF2/3P-24 |
Prime Power (50Hz) | 24KW / 30KVA |
Standby Power (50Hz) | 26KW / 33KVA |
Frequency / Speed | 50Hz / 1500rpm |
Standard Voltage | 230V / 400V |
Voltage Available | 220V / 380V |
Phase Configuration | Three Phase, Four Wires |
Engine Performance and General Info | |
Manufacturer: | UK Perkins Engine Co. Ltd. |
Engine Model: | 404A-22G1 |
Engine Type: | 4 Stroke, Vertical Inline, 3-Cylinder |
Engine Speed: | 1500 r.p.m |
Prime Power: | 28kW / 37HP |
Lubrication Oil: | CH4 / 15W-40 |
Lubrication Oil Capacity: | 7.9L |
Governor Type: | Mechanical |
Displacement: | 3.3L |
Cylinder Bore × Stroke: | 105mm × 127mm |
Compression Ratio: | 23.3:1 |
Coolant Capacity: | 10.2 Liters |
Alternator Data | |
Alternator Model: | Stamford PI144G |
Phase | 3 Phase |
Power Factor | 0.8 |
Drip Proof Rating | IP 23 |
Insulation Class | H |
Voltage Regulation | ± 0.5 % |
Altitude Limit | ≤ 1000 m |
Over Speed Limit | 2250 minâ»Â¹ |
Â
Standard Equipment Included:
1) Heavy-duty industrial diesel engine with option to choose famous brands.
2) Brushless alternator with single bearing, flange connection, IP23 rating, H insulation class, and AVR.
3) Auto control panel with LCD display for easy monitoring.
4) Battery-charging alternator mounted on the engine for reliable power supply.
5) Circuit breaker and exhaust silencer included.
6) Copper radiator designed for 40°C ambient temperature with double-deck cooling and protective guards.
7) Anti-vibration pads ensure stable operation between engine and base frame.
8) Skid-mounted 8-hour fuel tank for extended runtime.
9) External emergency stop button for added safety.
10) Optional features: Soundproof canopy, ATS, AMF panel, trailer, and parallel system.
Â
Optional Add-ons:
-- Automatic Transfer Switch
-- Soundproof Canopy
-- Under-base Fuel Tank
-- Oil Filter
Â
AMF Control Panel - ComAp AMF20 or DSE7320
Brand | Deepsea / ComAp |
The control module provides digital readouts of: - Generator voltage - Output frequency - Engine speed - Battery voltage - Engine operating hours It also includes failure indicators such as: - Overspeed / Underspeed - Emergency stop - Low oil pressure - High water temperature - Failure to start - Battery charger failure Automatic shutdown occurs under: - Low oil pressure - High water temperature - Overspeed / Underspeed - Failure to start after three attempts. |
![]() |
FAQ (Frequently Asked Questions): 1. What is your warranty period? Our standard warranty is 1 year or 1000 running hours, whichever comes first. For special projects, we can extend the warranty period upon request. 2. Do you offer global warranty? Yes, most of our generators, including those from Cummins, Perkins, and Doosan, come with global warranty service. Alternators like Leroysomer and Stamford also have global coverage, ensuring reliable after-sales support worldwide. 3. Can you accept OEM orders? Yes, we do accept OEM orders and can customize products according to your requirements. 4. What are your payment terms? We accept T/T with 30% deposit and 70% balance before shipping, or L/C at sight, L/C deferred, or Western Union. 5. How long is your delivery time? Normal delivery time is 2–5 weeks. If your order involves special engines or alternators, the delivery time may be longer. |
Â
Contact Us:
Ms. Hebe Wang
Â
Guangdong Heidler Technology Co., Ltd , https://www.hyhemit.com